DPA 3511A - complete stereo kit with two 4011A Cardioid Microphones, carefully factory-matched
Matched stereo pairs
- Modularity – interchangable capsules and preamplifiers
- Up to 120 dB dynamic range
- RF rejection between >60 and >40 dB
- Linear frequency response
- High SPL
- Superior gain before feedback
3511A Stereo Kit with 4011A Cardioids
This is a complete stereo kit with two 4011A Cardioid Microphones, carefully factory-matched within ±1 dB on frequency response and sensitivity in the microphone’s entire frequency bandwidth. The kit includes mics, windscreens, boom, holders, clips, and much more.
The 4011A Cardioid Microphone is renowned in recording studios and live applications around the world as an exceptional mic. State-of-the-art components have been carefully selected to provide optimal neutrality, accuracy and extremely low distortion.
The 4011 Cardioid Microphone
The principal appeal of the 4011 Cardioid Microphone is its directional quality and attention to detail. This mic makes everything sounds like the original. The first-order cardioid pickup pattern provides superb separation between sound sources.
It is equally suitable for close-up work on acoustic guitar, grand piano, overheads, percussion, wind instruments and vocals as it is for spot-miking symphonies. It can handle incredibly high sound levels and even includes a 20 dB pad switch in the center of the XLR connector to attenuate the output of the microphone.
A flat on-axis frequency response and excellent phase response deliver a totally faithful reproduction of the original sound. The off-axis response is similarly smooth so that any leakage is an accurate reflection of the original, though attenuated according to the true first-order cardioid pickup pattern.
Specifications
Directional pattern: Cardioid
Principle of operation: Pressure gradient
Cartridge type: Pre-polarized condenser
Frequency response: 20 Hz - 20 kHz
Effective frequency range, ±2 dB, at 30 cm (11.8 in): 40 Hz - 20 kHz
Sensitivity, nominal, ±2 dB at 1 kHz: 10 mV/Pa; -40 dB re. 1 V/Pa
Equivalent noise level, A-weighted: Typ. 18 dB(A) re. 20 µPa (max. 20 dB(A))
Equivalent noise level, ITU-R BS.468-4: Typ. 25 dB (max. 27 dB)
Distortion, THD < 1%: 136 dB SPL RMS, 139 dB SPL peak
Dynamic range: Typ. 121 dB
Max. SPL, THD 10%: 159 dB SPL peak
Switchable attenuator, filters etc.: 0 dB / -20 dB
Rated output impedance: 200 Ω
Minimum load impedance: 2 kΩ
Cable drive capability: 100 m (328 ft)
Output balance principle: Impedance balancing with Active Drive
Common mode rejection ratio (CMRR): > 60 dB
Power supply (for full performance): P48 (Phantom Power)
Current consumption: 2.8 mA
Connector: XLR-3M. Pin 1: shield, Pin 2: signal + phase, Pin 3: - phase
Color: Matte black
Weight: 158 g (5.6 oz)
Microphone diameter: 19 mm (0.75 in)
Capsule diameter: 19 mm (0.75 in)
Microphone length: 170 mm (6.7 in)
Maximum output voltage, RMS: 8 V
Polarity: +V at pin 2 for positive sound pressure
Temperature range: -40°C to 45°C (-40°F to 113°F)
Relative humidity (RH): Up to 90%
Matching tolerance (frequency response and sensitivity): ±1 dB
Phase deviation for kit: < 10°
4011A Frequency response
Typical on and off-axis response of a 4011A Cardioid Microphone measured at 30 cm (11.8 in)